Description
Technical Data
Technical Data
Frame | 182/4JM |
---|---|
Output | 5 HP (3.7 kW) |
Number of Poles | 2 |
Frequency | 60 Hz |
Rated speed | 3500 rpm |
Slip | 2.78 % |
Rated voltage | 115/208-230 V |
Rated current | 39.5/22.0-19.7 A |
L. R. Amperes | 265/147-132 A |
LRC | 6.7x(Code G) |
No load current | 10.4/3.00-5.20 A |
Rated torque | 7.50 ft.lb |
Locked rotor torque | 175 % |
Breakdown torque | 250 % |
Locked rotor time | 16s (cold) 9s (hot) |
Moment of inertia (J) | 0.1566 sq.ft.lb |
Design | L |
Insulation Class | F |
Service factor | 1.15 |
Temperature rise | 80 K |
Duty Cycle | Cont.(S1) |
Starting Method | Direct On Line |
Ambient temperature | -20°C to +40°C |
Altitude | 1000 m.a.s.l. |
Enclosure | IC01 – ODP |
Mounting | F-1 |
Rotation¹ | Both (CW and CCW) |
Approx. weight³ | 81.6 lb |